Model
|
WAW-100
|
WAW-300
|
WAW-600
|
WAW-1000
|
WAW-2000
|
WAW-3000
|
|||
Maximum test force
|
100kN
|
300kN
|
600kN
|
1000kN
|
2000kN
|
3000kN
|
|||
Host structure
|
Two column
|
Two column
|
Four column
|
Four column
|
Four column
|
Four column
|
|||
Indication accuracy
|
±1% or ±0.5%
|
||||||||
Load resolution (KN)
|
1/300000
|
||||||||
Effective measurement range (KN)
|
2%~100%
|
||||||||
Deformation accuracy
|
Better than ±0.5%
|
||||||||
Deformation Resolution (μm)
|
2
|
||||||||
Displacement indication Accuracy
|
Better than ±1%
|
||||||||
Stress control speed (Mpa / s)
|
1~45
|
||||||||
Strain control speed (mm / s)
|
0.001~0.5
|
||||||||
Displacement control speed (mm / s)
|
0.02~3
|
||||||||
Testing space
|
Stretching space (mm)
|
600
|
600
|
600
|
650
|
750
|
800
|
||
Compression space (mm)
|
550
|
550
|
550
|
580
|
650
|
700
|
|||
effective width(mm)
|
460
|
460
|
500
|
520
|
650
|
750
|
|||
Cylinder(mm)
|
200
|
200
|
250
|
250
|
250
|
250
|
|||
Host
Size(mm)
|
hydro-cylinder underneath type (Double space)
|
720×580
×1770
|
720×580
×1770
|
800×620
×2050
|
860×660
×2170
|
950×620
×3000
|
1100×750
×3100
|
||
hydro-cylinder placed up type(Single space)
|
850×540
×2600
|
850×540
×2600
|
980×640
×3100
|
1100×720
×3700
|
1300×900
×4300
|
1300×900
×4300
|
|||
Round sample size(mm)
|
Φ5~Φ20
|
Φ10~Φ32
|
Φ13~Φ40
|
Φ20~Φ60
|
Φ20~Φ80
|
Φ20~Φ100
|
|||
Flat sample size (thickness × width mm)
|
0~15×75
|
0~15×75
|
0~30×80
|
0~40×110
|
10~60×120
|
10~80×120
|
|||
Total power(kw)
|
2.1
|
2.1
|
2.3
|
2.3
|
3.5
|
5
|
|||
Voltage
|
220V and 380V ( Can configured with national standard voltage)
|
||||||||
Weight(kg)
|
1500
|
1500
|
2500
|
3100
|
5000
|
6500
|