NB-5510 고성능 액체 크로마토 그래프
응용 프로그램
HPLC는 고비 점, 저 휘발성, 고 분자량, 다양한 극성 및 열 안정성이 낮은 유기 화합물의 분석에 널리 사용됩니다. HPLC는 생물학적 활성 물질, 고분자, 천연 고분자 화합물 등을 분석하는 데 사용됩니다.
Medicine and Life Sciences |
Research and development of new drugs, biological functional deconstruction, quality control |
Sanitation and Disease Control |
Clinical analysis, human biochemical indexes analysis, metabolite analysis |
Food Processing |
Nutritional analysis, functional food research, antimicrobial residues, pesticide residues and |
|
additives analysis. |
Chemical Industry |
Functional studies, quality control |
Environmental Protection |
Monitoring water quality, air quality, marine environment, detection of various contaminants |
Quality Supervision |
Commercial inspection, quality inspection, import and export inspection and quarantine |
Education and Research |
Experiments, scientific research and teaching |
Other Areas |
Water plants, power plants, judicial and public security departments |
풍모
높은 자동화
파장 선택, 온도 제어 및 반도체 냉각은 소프트웨어를 통해 제어됩니다.
모듈 형 구조 : 매력적이고 합리적인 디자인
고성능 가변 파장 UV-Vis 검출기
• 고감도, 저소음 및 드리프트
• 새로운 광학 디자인, 오목한 홀로그래피 격자 제공
높은 반복성
• 넓은 파장 범위, 다중 파장 프로그래밍,
연속 흐름으로 전체 파장 스캐닝,
최적의 분석 파장을 정확하게 선택합니다.
• R232 데이터 인터페이스
• 긴 수명의 중수소 램프, 일반 수명 2000 년
몇 시간 이상
정밀 자동 온도 조절 컬럼 오븐
• 대형 오븐은 수동 주입기와 두 개의 기둥 (15 cm, 25 cm, 30 cm)을 수용 할 수 있습니다.
• 생물 시료의 저온 분리에 적합한 고급 온도 제어
• 정확한 온도 제어, 상태 패널의 온도 디스플레이, 과열 알람 및 보호 (자동 종료).
6 방향 밸브
6 웨이 밸브 분사는 국제 표준과 호환됩니다. 사용하기 쉽고, 저소음, 정확한 분사.
P-101A 고압 펌프
•이 듀얼 피스톤 왕복동 고압 펌프는 고정밀 흐름을 유지합니다. 고품질의 씰 링은 마모, 압력 및 부식에 강합니다. 특허받은 펄스 감쇠기는 효과적인 감쇠를 보장합니다. 그래디언트 용출은 소프트웨어에 의해 제어됩니다.
• 낮은 펄스, 큰 유량 범위, 지속적으로 조정 가능한 유량, 높은 유량 반복성, 접근 가능한 솔벤트 교체.
• 압력 모니터링 및 안전 메커니즘, 프로그램 된 흐름 및 시간 제어 기능을 갖추고 있습니다.
• 간편한 유지 보수 : 펌프는 세척, 수리 및 유지 보수가 쉽고 플런저로드 및 씰은 청소가 가능하며 쉽게 교체 할 수 있습니다. 플런저로드를 청소하면 염분 완충액 침착으로 인한 마모를 최소화 할 수 있습니다.
LC 소프트웨어
• 사용하기 쉽고 직관적 인 펌프 및 검출기 제어
• 다양한 양적 알고리즘을 특징으로하는 강력한 데이터 처리 기능.
• 강력한 크로마토 그램 비교 기능
• 보정 곡선 보정 기능
• 높은 수준의 자동화 : 데이터 수집에서 보고서 인쇄까지의 전 과정이 자동화됩니다. 일련의 크로마토 그램을 파일로 저장하여 편리하게 관리 할 수 있습니다.
• 원시 크로마토 그램 수집 데이터 및 관련 정보는 GLP 표준을 준수하여 기록됩니다.
• 보고서 출력 형식의 유연한 디자인
• 요구 사항에 따라 계측기 정보를 설정하십시오.
기술 사양
고압 펌프
Working pressure |
0-42MPa |
Flow range |
0.001 - 15.00 mL/min (maximum flow 50.00 mL/min, |
|
suitable for semi-prep) |
Flow accuracy |
RSD<0.1% |
Gradient range |
Isocratic, binary gradient |
Set value error |
±0.2% |
of pump flow |
|
|
|
Column Oven
Temperature range |
Semiconductor cooling 5℃~80℃ (ambient temperature <25℃) |
Temperature accuracy |
±0.1℃ |
|
|
오븐은 두 개의 서로 다른 기둥 (15cm, 20cm, 25cm, 30cm)을 동시에 설치할 수 있습니다.
UV-Vis 검출기
Light source |
Deuterium lamp |
|
Wavelength range |
190nm~700nm |
|
Spectral bandwidth |
5nm |
|
Wavelength indication error |
±0.2nm |
|
Wavelength accuracy |
≤0.2nm |
|
Wavelength scanning |
Multi-wavelength programming (10 wavelength ranges) |
|
Range of linearity |
>104 |
|
Noise |
<1×10-5 AU (empty cell), |
|
|
<2.0×10-5 AU (with mobile phase, dynamic) |
|
Drift |
<3×10-4 AU (empty cell), |
|
|
<3×10-4 AU (with mobile phase, dynamic) |
|
Cell width |
4.5mm |
|
Minimum detectable |
4×10-8 g/ml(naphthalene) |
|
concentration |
|
|
|
Technical Specifications of the AS-401 Autosampler
Performance Specifications
Repeatability |
RSD<0.5% |
Linearity |
>0.999 |
Residual cross-contamination |
<0.01% |
Specifications
Sample positions |
2×60 positions, 1.8 mL vials |
Minimum injection volume |
0.1 µL (250µL standard sample pump) |
Injection pump |
100 µL, 250µL (standard), 1 mL ... |
Sampling loop volumn |
100µL (standard), 20µL, 50µL, 200µL (options) |
Switching rate of |
< 100 ms |
sampling valve |
|
Position accuracy |
< 0.3 mm |
Motion control method |
XYZ 3-dimension coordinate system |
Injector cleaning method |
Inside and outside rinse, no restrictions on rinse times |
Number of replicates |
No restrictions on replicates |
Dimensions |
300 (W) × 230 (H) × 505 (D) mm |
Power |
AC 220 V, 50 Hz |
Compatibility |
Compatible with all commercial HPLC / IC systems |
Temperature range |
10 - 40℃ |
pH range |
1-14 |
DM-100/DM-101 Online Degasser
Applications |
Compatible to all HPLC, easy to install |
Features |
High degassing efficiency, smooth baseline, no drift, and low noise |
Basic Configuration |
Single-channel, three-channel or four-channel degassing systems |
are available. |
Degasser is available in a horizontal or vertical orientation |
according to customer requirements. |